D-XTR-DY-A-24 Valid Vce Dumps - D-XTR-DY-A-24 Updated Demo

Tags: D-XTR-DY-A-24 Valid Vce Dumps, D-XTR-DY-A-24 Updated Demo, D-XTR-DY-A-24 Exams Torrent, D-XTR-DY-A-24 Latest Braindumps Book, D-XTR-DY-A-24 Test Guide

The Dell XtremIO Deploy Achievement real dumps by PassTorrent that are available in three formats get updates every three months as per the feedback received from industry professionals. When you will buy the EMC D-XTR-DY-A-24 pdf questions and practice tests, you can open and access them instantly. The EMC D-XTR-DY-A-24 Practice Tests software is also updated if the EMC D-XTR-DY-A-24 certification exam content changes. You can download a free demo of EMC D-XTR-DY-A-24 PDF dumps and practice software before buying.

EMC D-XTR-DY-A-24 Exam Syllabus Topics:

TopicDetails
Topic 1
  • XtremIO X1 and X2 Management: In this section of the exam, for storage system managers and administrators, this section of the exam covers storage management operations using GUI, CLI, and REST, including user accounts and access methods.
Topic 2
  • XtremIO X1 and X2 Initial Configuration: For storage system administrators and configuration specialists, this part of the exam covers XtremIO Management Server (XMS) installation options, requirements, and deployment considerations.
Topic 3
  • XtremIO X1 and X2 Installation: For storage implementation specialists and system integrators, this domain covers required documentation for installations, including document usage order, cabling requirements for single and multi-cluster setups, logical order of installation operations post-cabling, up to cluster format, and post-installation procedures and processes.
Topic 4
  • XtremIO X1 and X2 Solution Integration: For solution architects and integration specialists, this domain covers recoverPoint, VPLEX, and AppSync options, considerations, limitations, and use cases

>> D-XTR-DY-A-24 Valid Vce Dumps <<

Reasons To Buy EMC D-XTR-DY-A-24 Exam Dumps

PassTorrent provides 24/7 customer support to answer any of your queries or concerns regarding the Dell XtremIO Deploy Achievement (D-XTR-DY-A-24) certification exam. They have a team of highly skilled and experienced professionals who have a thorough knowledge of the Dell XtremIO Deploy Achievement (D-XTR-DY-A-24) exam questions and format.

EMC Dell XtremIO Deploy Achievement Sample Questions (Q52-Q57):

NEW QUESTION # 52
What is the correct sequence of steps to create a new XtremIO X1 cluster from an existing XMS?

Answer:

Explanation:

Explanation:
Log into the existing XMS as "tech"
Select "Install Storage Controller only"
Log into the existing XMS Easy-Install menu
Install the components and prepare the Storage Controllers
Issue the create-cluster command
* Log into the existing XMS as "tech": Begin by logging into the existing XtremIO Management Server (XMS) using the "tech" user account, which has the necessary privileges to perform installation and configuration tasks.
* Select "Install Storage Controller only": Choose the option to install only the storage controller to ensure the proper setup of the storage controllers in the cluster.
* Log into the existing XMS Easy-Install menu: Access the Easy-Install menu on the XMS to guide you through the setup process.
* Install the components and prepare the Storage Controllers: Follow the instructions to install all necessary components and prepare the storage controllers for integration into the cluster.
* Issue the create-cluster command: Finally, execute the create-cluster command to officially create and configure the new XtremIO X1 cluster within the XMS.
References:
* Dell XtremIO Installation and Setup Guide
* Dell XtremIO Deployment Services
* XtremIO Management Server (XMS) Documentation


NEW QUESTION # 53
After the XtremlO X1 has been racked and the cabling has been checked, you now need to power on the XtremIO. What are the documented sequence of steps to power on the XtremIO?

Answer:

Explanation:

Explanation:
Power the PDUs
Power on the BBUs
Power on the Storage Controllers
Power on the physical XMS Server
* Power the PDUs: The Power Distribution Units (PDUs) need to be powered first as they supply power to all the other components.
* Power on the BBUs: The Battery Backup Units (BBUs) are powered on next to ensure that the system has emergency power in case of a power failure.
* Power on the Storage Controllers: The storage controllers are responsible for managing the storage array, so they need to be powered on before the server.
* Power on the physical XMS Server: Finally, the XMS server, which provides management and monitoring capabilities, is powered on.
References:
* Dell XtremIO Deployment Services
* Dell XtremIO Deployment Guide and official documentation for detailed step-by-step procedures.


NEW QUESTION # 54
You are filling out the Site Preparation form for an XtremlO X2 two X-Brick system installation. Why are only two IP addresses required?

  • A. Second X-Brick assumes the addresses if the first X-Brick fails over
  • B. X2 systems are managed through only the first X-Brick
  • C. A form from an X1 installation was used
  • D. X2 systems are managed only through odd numbered X-Bricks

Answer: B

Explanation:
For an XtremIO X2 two X-Brick system installation, only two IP addresses are required because the entire system is managed through the first X-Brick. This is in line with the design of the XtremIO X2 architecture, which allows for a single management point for multiple X-Bricks. The XMS (XtremIO Management Server) manages multiple XtremIO arrays and requires an IP address for each X-Brick in the cluster1. In a two X-Brick system, the first X-Brick acts as the primary management point, and the second X-Brick is managed through it, thus only necessitating two IP addresses for management purposes2.


NEW QUESTION # 55
Based on the XtremIO X1 Storage Array Software Installation and Upgrade Guide, what is the correct sequence of installation steps?

Answer:

Explanation:

Explanation:
Install the XMS Server
Install the Storage Controllers
Initialize the Cluster Services
Configure ESRS
Generate an XtremIO Log Bundle
* Install the XMS Server: The XtremIO Management Server (XMS) must be installed first, as it is the central management point for the XtremIO storage array.
* Install the Storage Controllers: After setting up the XMS, the next step is to install the storage controllers, which are the main components of the XtremIO array responsible for handling data operations.
* Initialize the Cluster Services: Once the storage controllers are installed, you need to initialize the cluster services to configure and prepare the storage array for operation.
* Configure ESRS (EMC Secure Remote Services): After the cluster services are initialized, configure ESRS for remote support and monitoring, ensuring that the system can be supported remotely by Dell EMC.
* Generate an XtremIO Log Bundle: Finally, generate an XtremIO log bundle for initial diagnostics and baseline information. This step ensures that all necessary logs are collected and can be reviewed if needed.
References:
* Dell XtremIO X1 Storage Array Software Installation and Upgrade Guide
* Dell XtremIO Deployment Services
* XtremIO X1 User and Maintenance Guide


NEW QUESTION # 56
After the XtremlO X1 has been racked and the cabling has been checked, you now need to power on the XtremIO. What are the documented sequence of steps to power on the XtremIO?

Answer:

Explanation:

1 - Power on the Storage Controllers.
2 - Power on the physical XMS server.
3 - Power on the BBUs
4 - Power the PDUs


NEW QUESTION # 57
......

Opportunities are very important in this society. With the opportunity you can go further. However, it is difficult to seize the opportunity. Is your strength worthy of the opportunity before you? In any case, you really need to make yourself better by using our D-XTR-DY-A-24 training engine. With our D-XTR-DY-A-24 Exam Questions, you can equip yourself with the most specialized knowledage of the subject. What is more, our D-XTR-DY-A-24 study materials can help you get the certification. Imagine you're coming good future maybe you will make a better choice!

D-XTR-DY-A-24 Updated Demo: https://www.passtorrent.com/D-XTR-DY-A-24-latest-torrent.html

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Comments on “D-XTR-DY-A-24 Valid Vce Dumps - D-XTR-DY-A-24 Updated Demo”

Leave a Reply

Gravatar